- There are no suggestions because the search field is empty.

1. [TechShot](https://help.gen3systems.com/techshot?hsLang=en)
2. [FAQs](https://help.gen3systems.com/techshot/faqs?hsLang=en)
3. [CM Series - Ionic Contamination Testing](https://help.gen3systems.com/techshot/faqs?hsLang=en#cm-series-ionic-contamination-testing)

August 12, 2026

# What does 6 Sigma Verification mean on my CM?

## In a collaborative project with Robert Bosch Gen3 achieved 6 sigma verification on our CM+ Ionic Contamination testing equipment – the only Ionic contamination testers in the world that have achieved this. But what exactly does 6 sigma mean in this context?

![](https://help.gen3systems.com/hs-fs/hubfs/undefined.png?width=86&height=77&name=undefined.png)

The increasing use of electronic control units in harsh environments, in, especially, high reliability, safety-critical applications, demands full understanding and rigorous control of electrochemical reliability.

The production of electronic circuits involves more than 20 individual chemical process steps, most of which contain high levels of ionic matter. Electric potentials when combined with a damp or moist operating environment, coupled with the presence of ionic matter, can often increase the probability for dendritic, electrochemical reactions and premature, unpredictable circuit failures.

For these reasons the analysis of the surface insulation resistance (SIR) can be employed to assess electrochemical reliability of assemblies and thereby establish a qualified manufacturing process.

The increasing use of electronic control units in harsh environments, in, especially, high reliability, safety-critical applications, demands full understanding and rigorous control of electrochemical reliability.

The production of electronic circuits involves more than 20 individual chemical process steps, most of which contain high levels of ionic matter. Electric potentials when combined with a damp or moist operating environment, coupled with the presence of ionic matter, can often increase the probability for dendritic, electrochemical reactions and premature, unpredictable circuit failures.

For these reasons the analysis of the surface insulation resistance (SIR) can be employed to assess electrochemical reliability of assemblies and thereby establish a qualified manufacturing process

- [FAQs](https://help.gen3systems.com/techshot/faqs?hsLang=en#main-content)

    - [CM Series - Ionic Contamination Testing](https://help.gen3systems.com/techshot/faqs?hsLang=en#cm-series-ionic-contamination-testing)
    - [AutoSIR2+ Surface Insulation Resistance Testing](https://help.gen3systems.com/techshot/faqs?hsLang=en#autosir2-surface-insulation-resistance-testing)
- [Getting started](https://help.gen3systems.com/techshot/getting-started?hsLang=en#main-content)

    - [CM Series - Ionic Contamination Testing](https://help.gen3systems.com/techshot/getting-started?hsLang=en#cm-series-ionic-contamination-testing)
    - [MUST3](https://help.gen3systems.com/techshot/getting-started?hsLang=en#must3)
- [Troubleshooting](https://help.gen3systems.com/techshot/troubleshooting?hsLang=en#main-content)

    - [MUST3 - Solderability Testing](https://help.gen3systems.com/techshot/troubleshooting?hsLang=en#must3-solderability-testing)
    - [CM Series - Ionic Contamination Testing](https://help.gen3systems.com/techshot/troubleshooting?hsLang=en#cm-series-ionic-contamination-testing)
- [General](https://help.gen3systems.com/techshot/general?hsLang=en)
- [Objective Evidence](https://help.gen3systems.com/techshot/objective-evidence?hsLang=en#main-content)

    - [Objective Evidence](https://help.gen3systems.com/techshot/objective-evidence?hsLang=en#objective-evidence)

[![Shield-Orange](https://help.gen3systems.com/hs-fs/hubfs/Branding/Shield-Orange.png?width=100&height=100&name=Shield-Orange.png "Shield-Orange")](https://www.gen3systems.com/)

B2, ARMSTRONG MALL, SOUTHWOOD BUSINESS PARK, FARNBOROUGH, HAMPSHIRE, GU14 0NR

<https://www.facebook.com/> <https://www.twitter.com/> <https://www.instagram.com/> <https://podcasts.apple.com/> [mailto:email@email.com](mailto:email@email.com)

Copyright © 2026, GEN3